RCD Series - Cycling Refrigerated Dryers
Air Treatment Filters & Accessories
Energy Savers
Gardner Denver RCD cycling refrigerated dryers provide stable 33–39°F pressure dew point control with automatic energy savings operation. Cold energy storage system is precision engineered to guarantee that the refrigeration compressor uses no energy for at least 10 minutes during every cycle.
The controller continuously monitors the cold energy solution temperature to maintain the dew point selected and maximize energy efficiency. Ample solution volume and temperature controls ensure the continuous delivery of dry compressed air long after the refrigeration compressor has turned off.
Voltage: 208–230/1/60 available on RCD200–600 models. 208–230/3/60 additional charge on RCD3250–12000 models. 575/3/60 additional charge on all models.
De-rate dryer capacity by 17% for 50 Hz.
Standard dryer enclosures and controls meet NEMA1.
For 208–230/3/60 incoming power applications, purchase 230/1/60 and simply drop a leg at installation (200–600 only.)
Models 200–600: Maximum operating pressure 225 psig; Maximum inlet temperature 120°F
Models 3250–12000: Maximum operating pressure 150 psig; Maximum inlet temperature 130°F; ASME pressure vessel; UL listed refrigeration and electrical components; CSA listed electrical components
Gardner Denver RCD cycling refrigerated dryers provide stable 33–39°F pressure dew point control with automatic energy savings operation. Cold energy storage system is precision engineered to guarantee that the refrigeration compressor uses no energy for at least 10 minutes during every cycle.
The controller continuously monitors the cold energy solution temperature to maintain the dew point selected and maximize energy efficiency. Ample solution volume and temperature controls ensure the continuous delivery of dry compressed air long after the refrigeration compressor has turned off.
Voltage: 208–230/1/60 available on RCD200–600 models. 208–230/3/60 additional charge on RCD3250–12000 models. 575/3/60 additional charge on all models.
De-rate dryer capacity by 17% for 50 Hz.
Standard dryer enclosures and controls meet NEMA1.
For 208–230/3/60 incoming power applications, purchase 230/1/60 and simply drop a leg at installation (200–600 only.)
Models 200–600: Maximum operating pressure 225 psig; Maximum inlet temperature 120°F
Models 3250–12000: Maximum operating pressure 150 psig; Maximum inlet temperature 130°F; ASME pressure vessel; UL listed refrigeration and electrical components; CSA listed electrical components
Item # |
Flow |
Pressure Drop |
Compressor |
In/Out Connection |
Weight |
Max Working Pressure Range |
Inlet Temp. Range |
---|---|---|---|---|---|---|---|
RCD200 RCD200/Asset/RCD-Series.JPG | Flow N/A 200 | Pressure Drop N/A 3.1 | Compressor N/A 2 hp | In/Out Connection N/A 2 in | Weight N/A 1040 lb | Max Working Pressure Range N/A 30 to 225 psig | Inlet Temp. Range N/A +40 to 120 ºF |
RCD300 RCD300/Asset/RCD-Series.JPG | Flow N/A 300 | Pressure Drop N/A 4.8 | Compressor N/A 2 1/2 hp | In/Out Connection N/A 2 in | Weight N/A 1067 lb | Max Working Pressure Range N/A 30 to 225 psig | Inlet Temp. Range N/A +40 to 120 ºF |
RCD400 RCD400/Asset/RCD-Series.JPG | Flow N/A 400 | Pressure Drop N/A 4.1 | Compressor N/A 2 3/4 hp | In/Out Connection N/A 2 1/2 in | Weight N/A 1101 lb | Max Working Pressure Range N/A 30 to 225 psig | Inlet Temp. Range N/A +40 to 120 ºF |
RCD500 RCD500/Asset/RCD-Series.JPG | Flow N/A 500 | Pressure Drop N/A 5.0 | Compressor N/A 3 hp | In/Out Connection N/A 2 1/2 in | Weight N/A 1114 lb | Max Working Pressure Range N/A 30 to 225 psig | Inlet Temp. Range N/A +40 to 120 ºF |
RCD600 RCD600/Asset/RCD-Series.JPG | Flow N/A 600 | Pressure Drop N/A 4.1 | Compressor N/A 3 1/2 hp | In/Out Connection N/A 2 1/2 in | Weight N/A 1146 lb | Max Working Pressure Range N/A 30 to 225 psig | Inlet Temp. Range N/A +40 to 120 ºF |
RCD3250 RCD3250/Asset/RCD-Series.JPG | Flow N/A 3250 | Pressure Drop N/A 5.0 | Compressor N/A 15 hp | In/Out Connection N/A 6 in | Weight N/A 6500 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |
RCD4000 RCD4000/Asset/RCD-Series.JPG | Flow N/A 4000 | Pressure Drop N/A 5.0 | Compressor N/A 20 hp | In/Out Connection N/A 8 in | Weight N/A 10100 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |
RCD5000 RCD5000/Asset/RCD-Series.JPG | Flow N/A 5000 | Pressure Drop N/A 5.0 | Compressor N/A 22 hp | In/Out Connection N/A 8 in | Weight N/A 12400 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |
RCD6250 RCD6250/Asset/RCD-Series.JPG | Flow N/A 6250 | Pressure Drop N/A 5.0 | Compressor N/A 30 hp | In/Out Connection N/A 8 in | Weight N/A 15150 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |
RCD8250 RCD8250/Asset/RCD-Series.JPG | Flow N/A 8250 | Pressure Drop N/A 5.0 | Compressor N/A 35 hp | In/Out Connection N/A 8 in | Weight N/A 16000 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |
RCD10000 RCD10000/Asset/RCD-Series.JPG | Flow N/A 10000 | Pressure Drop N/A 5.0 | Compressor N/A 50 hp | In/Out Connection N/A 10 in | Weight N/A 23000 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |
RCD12000 RCD12000/Asset/RCD-Series.JPG | Flow N/A 12000 | Pressure Drop N/A 5.0 | Compressor N/A 60 hp | In/Out Connection N/A 12 in | Weight N/A 28800 lb | Max Working Pressure Range N/A 30 to 150 psig | Inlet Temp. Range N/A +40 to 130 ºF |