Home
About Energy Machinery
Energy Conservation
Line Card
Contact Us
Request Information
Search Catalog
By Part Number
By Keyword
Products
Reciprocating Compressor
Rotary Screw Air
Compressors
Air Treatment Filters & Accessories
Lubricants & Repair Parts
Demand Expanders
Refrigerated Air Dryers
Centrifugal Compressors
Cycling Dryers
Variable Speed Compressors
Service, Parts and Rentals
Parts Department
Service Department
Rentals
Chicago Pneumatic Parts
Used Machinery
All Categories
>
Desiccant & Tower Dryers
>
HHS, HHL, and HHE Series Heatless Desiccant Air Dryers
>
Item # HHL-1550
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # HHL-1550, 1550 Standard Cubic Feet per Minute (scfm) Inlet Flow Capacity HHL Series Heatless Desiccant Air Dryer
List Price QUOTE
larger image
Hankison®'s Heatless Desiccant Dryers
The HHL Series
Utilizing twin towers filled with premium grade activated alumina, Hankison® Heatless dryers are available with three application specific control systems designed to meet the needs of specific industrial applications with economy and performance.
Specifications
·
ISO 8573.1 Quality Classes
·
Precision Performance
·
Application Specific Designs
·
Controller Features
·
Selectable Purge Economizer Savings
·
Inlet Flow
·
Four Dew Point Options per ISO 8573-1 Air Quality Standards
·
Dedicated to Excellence
·
Note
Specifications
Series
HHL
Brands
SPX®
Inlet Flow Capacity at 100 psig (6.7 bar) Pressure
1550
scfm
2634
nm³/h
Height
113
in
Width
66
in
Depth
56
in
Inlet Connection Size
3
in
Inlet Connection Type
ANSI Flange
Outlet Connection Size
3
in
Outlet Connection Type
ANSI Flange
Weight
4167
lb
Note for Connections
BSP and DIN flanges available.
Maximum Standard Working Pressure
1
150
psig
10.5
bar
Maximum Optional Working Pressure
250
psig
17.6
bar
Minimum Operating Pressure
60
psig
120
psig
150
psig
250
psig
4.2
bar
8.4
bar
10.5
bar
17.6
bar
Maximum Inlet Air or Ambient Air Temperature
120
ºF
49
ºC
Pressure Drop at Rated Flow
≤ 5
psi
≤ 0.35
bar
Available Voltage
100 to 240
V
Phase
1
Frequency
50 to 60
Hz
Direct Current (DC) Voltage
12 to 24
V
Industry Standards/Certifications
ANSI
ASME Approved
CRN
NEMA 4
Industry
Industries such as pharmaceutical manufacturing, laboratories, hospitals, microelectronics, food packaging, paper, glass and powder painting with low dew point requirements, utilize heatless desiccant air dryers.
1
Units with higher Maximum Working Pressures are available.
ISO 8573.1 Quality Classes
Dew Point
-100
ºF
38
ºF
-4
ºF
-40
ºF
-20
ºC
3
ºC
-40
ºC
-73
ºC
Remaining Moisture at Dew Point -100 ºF (-73 ºC)
0.12
ppmw
0.15
mg/m³
Remaining Moisture at Dew Point -40 ºF (-40 ºC)
10
ppmw
12
mg/m³
Remaining Moisture at Dew Point -4 ºF (-20 ºC)
81
ppmw
97
mg/m³
Remaining Moisture at Dew Point 38 ºF (3 ºC)
610
ppmw
730
mg/m³
Cycle Time for ISO Quality Class 1
4 min. Fixed
Cycle Time for ISO Quality Class 2
10 min. Fixed
Cycle Time for ISO Quality Class 3
16 min. Fixed
Cycle Time for ISO Quality Class 4
24 min. Fixed
Precision Performance
Industry-Leading Design
Consistent outlet pressure dew points
Premium grade desiccant beads enhance surface area and have high crush strength
Large desiccant beds ensure 4.8 seconds of contact time
Large flow diffusers ensure even flow distribution through the bed and eliminate channeling
Towers are designed to prevent fluidization of the desiccant
Up-flow drying allows water and heavy contaminants to drop out of the air stream
Simple discharge of contaminants
Cleanable stainless steel flow diffusers/support screens
Separate fill and drain ports for ease of desiccant replacement
Integrated Filtration
Optional pre-filter and after-filter packages, featuring Hankison® NGF Series filters, can be pre-installed at the
Grade SF and Grade HF pre-filters are recommended for -40 ºF to 38 ºF (-40 ºC to 3 ºC) dew points
Grade PF and Grade UF pre-filters are recommended for -100 ºF (-73 ºC) dew points
Grade PF and Grade CF are the recommended after-filters
Precision AccuShift™ Switching Valves
Automatically shift to the low pressure side of the circuit to control process flow
Position memory ensures drying continues even without power
5 year AccuShift™ valve replacement warranty
Three-way pilot operated solenoid valves manage the pilot air flow to direct the purge/repressurization valves
Purge pressure adjustment valve
1 Dryer must be protected by properly sized Hankison® prefilter. Parts and labor covered through first year of warranty, parts only in second through fifth years.
Engineered-to-Order Options
High dew point alarm which includes light and voltage free contacts for remote alarm
Dew point monitor, includes digital display, voltage-free contacts and recorder output
Low ambient packages, epoxy paint, severe environment protection
Oil-free packages with integrated activated carbon towers
Safety Built to Code
Pressure vessels are CRN and ASME Certified
Heavy-duty mufflers for quiet operation
NEMA 4 electrical construction is standard
Pressure relief valves are standard
Application Specific Designs
How it Works
Phase 1 - Moist, filtered compressed air enters the pressurized on-line desiccant-filled drying Tower 1 through the AccuShift™ valve (A).
Phase 2 - Up-flow drying enables the desiccant to strip the air stream of moisture. Clean, dry compressed air exits through AccuShift™ valve (B) to feed the air system.
Phase 3 - When in regeneration mode, Tower 2 depressurizes to atmosphere through the muffler (C) when the valve (D) opens.
Phase 4 - A portion of dry compressed air (purge air) is diverted before exiting (B) and passes through off-line Tower 2 and exits at valve (D) to desorb the moisture from the desiccant. Once desorbed, valve (D) closes and Tower 2 is repressurized.
Phase 5 - At tower shift-over, valve (E) will open, causing AccuShift™ Valves (A & B) to shift.
Phase 6 - Tower 2 will be placed on-line to dry the bed. Operations will switch and Tower 1 will be regenerated.
Controller Features
Choice of four fixed cycle operating modes corresponding to ISO 8573.1 Air Quality Classes
Choice of eight Purge Economizer Energy Savings settings
Switches for On/Off, Alarm and Service reminder reset
Operational LED lights for power-on, tower status, valve status, and tower pressure
Alarm LED for valve switching failure
RS-232 communications port is standard
Service reminder LED lights for filters and drains, valves and desiccant
Selectable Purge Economizer Savings
HHL Series provides user selectable energy savings with tailored drying cycles designed to match your peak air demands.
Reducing the amount of time the dryer spends purging in the regeneration cycle can save energy. Eight settings (0% to 70% in 10% increments) are furnished for users to lower the purge to match reduced air loads on the dryer. Each energy saving setting has an LED light which will illuminate when it is selected. Simply flip the switch to select the desired energy saving setting.
In addition, this state-of-the-art controller offers four pressure dew point settings to further tune your savings and adapt the system to your environment.
Inlet Flow
Inlet flow capacities are established in accordance with CAGI (Compressed Air and Gas Institute) standard ADF-200: Inlet air pressure 100 psig (6.7 barg), inlet temperature saturated at 100 ºF (38 ºC). To determine inlet flow at pressures other than 100 psig (6.7 barg), multiply inlet flow at 100 psig (6.7 barg) from Product Specifications by the corresponding multiplier.
Four Dew Point Options per ISO 8573-1 Air Quality Standards
Specifying a pressure dew point is not simple work for an engineer. Hankison® Heatless dryer designs allow you to optimize performance and dew points in the field to adapt to your environment and meet the following ISO 8573-1 Classes of air quality.
Dedicated to Excellence
Since 1948, compressed air users around the world have relied on Hankison® to provide innovative compressed air treatment solutions for critical applications.
Hankison® maintains a long standing reputation for manufacturing products that deliver superior performance, time proven reliability and optimal energy savings.
Hankison® today is the preferred choice for providing clean, dry compressed air for the most challenging industries.
Note
Dimensions and weights are for reference only. Request certified drawings for construction purposes.
MORE IMAGES
·
HHS, HHL, and HHE Series Heatless Desiccant Air Dryers - 2
·
HHS, HHL, and HHE Series Heatless Desiccant Air Dryers - 3
·
HHS, HHL, and HHE Series Heatless Desiccant Air Dryers Working
·
Multiplier Data for HHS, HHL, and HHE Series Heatless Desiccant Air Dryers
·
HHS/HHL Series Heatless Desiccant Air Dryer
·
Selectable Purge Economizer Savings Graph for HHL/HHE Series Heatless Desiccant Air Dryer
·
HHL Series Controller Features
Site created by
ThomasNet Web Solutions