Item # HF5-36-1, 1-1/4 or 1-1/2-GMTDS, 27 Inch (in) Height Modular Type Housing Grade 5 HF Series High Efficiency Oil Removal Air Filter
List Price QUOTE
larger image
Fine coalescer provides oil free air for industrial applications such as spray painting, injection molding, instrumentation and control valves.
Specifications
·
Technical Specifications
·
Air Quality/Pressure Drop
·
Additional Information
·
Quality Compressed Air
·
Engineered for Efficiency
·
Features
·
Element Grades for Enhanced Performance
·
Total System Protection
·
Accessories and Options
·
Versatile Installation
·
Pressure Monitoring
·
Condensate Management
·
Note
Specifications
Flow Capacity at 100 psig (6.7 bar) Pressure
375
scfm
637
nm³/h
Connection Size
1
in
1 1/4
in
1 1/2
in
Connection Type
NPT
Height
27
in
Width
6
in
Weight
11.3
lb
Replacement Element Model
E 5-36
Options
M (Electronic Filter Monitor)
T (Drain Plug)
D (Internal Automatic Drain)
S (Corrosion Proof Stainless Steel Element)
G (Differential Pressure Gauge)
Quantity
1
Series
HF
Brands
Hankison®
SPX®
Modular Housing Material
Aluminum
Steel
Zinc
Model
Modular Type Housings
Technical Specifications
Maximum Operating Pressure (Drain Plug)
300
psig
20.7
bar
Maximum Operating Temperature (Drain Plug)
150
ºF
66
ºC
Minimum Operating Temperature (Drain Plug)
35
ºF
2
ºC
Maximum Operating Pressure (Internal Automatic Drain)
250
psig
17.2
bar
Maximum Operating Temperature (Internal Automatic Drain)
150
ºF
66
ºC
Minimum Operating Temperature (Internal Automatic Drain)
35
ºF
2
ºC
Air Quality/Pressure Drop
Solid Particulate
0.01
µ
Remaining Oil
0.008
ppm
Dry Pressure Drop
1
psid
0.07
bar
Wet Pressure Drop
3
psid
0.21
bar
Additional Information
Hankison® filters remove more contaminants with less pressure drop through housings that have large flow areas. Compare the operating pressure drop of competitive brands and remember that for every extra 2 psi of pressure drop, power input needs to be increased by 1%. A systems approach has been used to allow for convenient matching of filter types to achieve the air quality you desire, while comprehensive third party testing guarantees performance to CAGI (Compressed Air And Gas Institute), ISO (International Standards Organization) and PNEUROP (European Committee of Manufacturers of Compressors, Vacuum Pumps and Pneumatic Tools) standards.
With a greater selection of filter grades, more models to choose from and worldwide technical and service support, Hankison® offers a systemized solution for your compressed air quality needs.
Quality Compressed Air
A typical compressed air system is contaminated with abrasive solid particles such as dust, dirt, rust and scale, compressor lubricants (mineral or synthetic), condensed water droplets and acidic condensates and oil and hydrocarbon vapors.
If not removed, these contaminants increase pneumatic equipment maintenance costs, lead to instrument and control failure, contribute to poor product fit and finish, and contaminate processes.
The right Hankison® filter or filter system will remove these contaminants allowing your compressed air system to deliver the quality of air required by your application - whether it's plant air, instrument air, medical air or helping to ensure consistent output quality while minimizing operating costs.
Engineered for Efficiency
Modular Housings for Flows through 780 scfm
Manufactured from top quality aluminum, zinc and steel
Chromated and epoxy powder painted (interior and exterior) for added durability and corrosion resistance
300 psig (21 bar) maximum working pressure (tested to a 5:1 safety factor)
Easy to Operate
Differential Pressure Gauge
Differential pressure indicators
Indicates optimum time for element change - maximizing your element investment while minimizing pressure drop
Large, easy to read gauge face
Dual faces allow housings to be mounted in any flow direction
Can be mounted remotely
Switch for remote indication available
Slide indicator
Changes color when filter element requires replacement
Liquid Level Indicator
Allows visual monitoring of liquid level and signals the need for preventative maintenance to avoid downstream contamination
Manufactured from thermoset polyurethane, compatible with synthetic lubricants
Internal Automatic Drains
Pilot operated, pneumatically actuated to reliably discharge collected liquid
Viton seals - compatible with synthetic lubricants
Inlet screen for additional protection
Discharge fitting threaded to facilitate drain line connection
Easy to Install
Modular connections allow housings to be connected in series easily, while saving space
Wall mounting bracket optional
Can be mounted for left or right entry
New space saving design reduces service clearances
Easy to Maintain
1/8 turn, self-locking bayonet head to bowl connections (through 1 in.)
Push on elements make element replacement quick and easy
If housing is not depressurized before disassembly, escaping air gives audible warning
Captive O-ring
Ribbed bowls allow use of C spanner
Color coded elements for easy identification
Features
Withstands temperatures to 150 ºF (66 ºC)
Push-on elements provide simple replacement
Piston type seal keeps unfiltered air from by-passing element
Stainless steel, corrosion resistant inner and outer cores
Low resistance to flow
Seam welded durability
Matrix blended fiber media
Large, effective surface area ensures high efficiencies and minimizes pressure drop
Coated, closed cell foam sleeve
Resists chemical attack from oils and acids
Ensures high efficiencies by preventing re-entrainment of coalesced liquids
Chemically resistant end caps
Silicone free
Element Grades for Enhanced Performance
Grade 5 High Efficiency Oil Removal Filter
Designed for coalescing fine water and oil aerosols
Removes solid particulate to 0.01 micron
Maximum remaining oil content (Filter efficiency has been established in accordance with CAGI standard ADF400 and is based on 100 ºF (38 ºC) inlet temperature.): 0.008 ppm w/w
Operation
First Stage - Multiple layers of fiber media and screen remove larger particles, pre-filtering the air
Second Stage - Multiple layers of bonded, blended fiber media for fine coalescence
Total System Protection
Element Grade
Grade 5
ISO Performance Data
Removes 99.9999+% of solids 0.01 micron and larger.
Remaining oil content < 0.08 ppm/w.
ISO 8573.1: 2010 Air Quality Class:
Solid Particles - Class 1.
Remaining Oil Content - Class 1.
Where Applied
Upstream of desiccant dryers
Downstream of refrigerated dryers
At point-of-use if aftercooler/separator installed upstream
Accessories and Options
The HF Series is supported by a complete line of accessories and options making filter installation and differential pressure monitoring easy.
Versatile Installation
Filter Connectors
Easily connects filters in series.
Wall Mount Bracket
Provides installation flexibility.
Pressure Monitoring
Differential Pressure Gauge
Two color gauge face indicates element change-out based on differential pressure.
Electronic Filter Monitor
Predicts the optimal time to change the element.
Condensate Management
No Air Loss Internal Float Drain
Effectively removes condensate without loss of air.
No Air Loss Mechanical Drain
Reliably removes condensate without need for electricity.
Note
Drain plugs standard. Externally mounted automatic drains are available.
Time-based Filter Monitor recommended.
MORE IMAGES
·
Grade 5 HF Series Compressed Air Filters - 2
·
Grade 5 HF Series Compressed Air Filters - 3
·
Grade 1 to Grade 11 HF Series Compressed Air Filters
·
Grade 1 to Grade 11 HF Series Compressed Air Filters - 2
·
Grade 1 to Grade 11 HF Series Compressed Air Filters - 3
·
Grade 1 to Grade 11 HF Series Compressed Air Filters - 4
·
Capacity Correction Factors for Grade 1 HF to 11 HF Series Compressed Air Filters
·
Filter Selection
·
Filter Connectors
·
Wall Mount Bracket
·
Differential Pressure Slide Indicator
·
Differential Pressure Gauge
·
Electronic Filter Monitor
·
Manual Drain
·
No Air Loss Internal Float Drain
·
No Air Loss Mechanical Drain
Site created by
ThomasNet Web Solutions