HBP Series Blower Purge Desiccant Compressed Air Dryers
New Products
HBP series dryers produce 100% efficient air systems.
Since 1948, compressed air users have relied on Hankison® to provide compressed air treatment solutions for applications around the world.
Since 1948, compressed air users have relied on Hankison® to provide compressed air treatment solutions for applications around the world.
Item # |
Item Name |
Inlet Flow at 100 psig with 100ºF Temperature |
Blower |
Heater Rated Output |
Average Full Load |
---|---|---|---|---|---|
HBP500 /Asset/a1557.jpg | N/A 10 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 500 scfm | Blower N/A 1.6 kW | Heater Rated Output N/A 10 kW | Average Full Load N/A 10 kW |
HBP600 /Asset/a1557.jpg | N/A 12 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 600 scfm | Blower N/A 2.5 kW | Heater Rated Output N/A 12 kW | Average Full Load N/A 12 kW |
HBP750 /Asset/a1557.jpg | N/A 14 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 750 scfm | Blower N/A 2.2 kW | Heater Rated Output N/A 14 kW | Average Full Load N/A 14 kW |
HBP900 /Asset/a1557.jpg | N/A 16 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 900 scfm | Blower N/A 2.0 kW | Heater Rated Output N/A 16 kW | Average Full Load N/A 16 kW |
HBP1050 /Asset/a1557.jpg | N/A 19 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 1050 scfm | Blower N/A 2.8 kW | Heater Rated Output N/A 19 kW | Average Full Load N/A 19 kW |
HBP1300 /Asset/a1557.jpg | N/A 23 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 1300 scfm | Blower N/A 5.3 kW | Heater Rated Output N/A 23 kW | Average Full Load N/A 25 kW |
HBP1500 /Asset/a1557.jpg | N/A 28 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 1500 scfm | Blower N/A 7.5 kW | Heater Rated Output N/A 28 kW | Average Full Load N/A 32 kW |
HBP1800 /Asset/a1557.jpg | N/A 32 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 1800 scfm | Blower N/A 7.0 kW | Heater Rated Output N/A 32 kW | Average Full Load N/A 35 kW |
HBP2200 /Asset/a1557.jpg | N/A 39 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 2200 scfm | Blower N/A 5.6 kW | Heater Rated Output N/A 39 kW | Average Full Load N/A 41 kW |
HBP2600 /Asset/a1557.jpg | N/A 45 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 2600 scfm | Blower N/A 10.3 kW | Heater Rated Output N/A 45 kW | Average Full Load N/A 50 kW |
HBP3200 /Asset/a1557.jpg | N/A 53 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 3200 scfm | Blower N/A 2.8 kW | Heater Rated Output N/A 53 kW | Average Full Load N/A 52 kW |
HBP3600 /Asset/a1557.jpg | N/A 58 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 3600 scfm | Blower N/A 4.0 kW | Heater Rated Output N/A 58 kW | Average Full Load N/A 59 kW |
HBP4300 /Asset/a1557.jpg | N/A 70 Kilowatt (kW) Heat Rated Output Compressed Air Dryer | Inlet Flow at 100 psig with 100ºF Temperature N/A 4300 scfm | Blower N/A 4.4 kW | Heater Rated Output N/A 70 kW | Average Full Load N/A 70 kW |