Print Back
Reliable Operation…

Customers around the world have relied on Hankison® for great value in air treatment solutions. Hankison® Value Line Refrigerated Dryers offer a simple solution based on a long history of industry leading technology.
Unit of Measure

Specifications

Rated Flow1 N/A 250 scfm425 m³/h

Refrigerant

N/A R134a

Voltage

N/A 460 V

Phase

N/A 3

Frequency

N/A 60 Hz

Power

N/A 1.98 kW

Inlet Connection Size

N/A 1 1/2 in

Inlet Connection Type

N/A NPT

Outlet Connection Size

N/A 1 1/2 in

Outlet Connection Type

N/A NPT

Height

N/A 30 in

Width

N/A 17 in

Depth

N/A 36 in

Weight

N/A 211 lb

Maximum Inlet Air Pressure

N/A 232 psig16 bar

Minimum Inlet Air Pressure

N/A 10 psig1 bar

Maximum Inlet Air Temperature

N/A 120 ºF49 ºC

Minimum Inlet Air Temperature

N/A 40 ºF4 ºC

Maximum Ambient Air Temperature

N/A 110 ºF43 ºC

Minimum Ambient Air Temperature

N/A 45 ºF7 ºC

Series

N/A Hankison® HRP HRPN

Ease of Monitoring

Ease of Monitoring

N/A
  • Model 75 -150 scfm : Lighted On/Off switch and dew point indicator.
  • Models 200 - 500 scfm: Lighted On/Off switch, LED dew point temperature indicator, timer drain adjustment on the panel.

Safety First - Environmental Friendly

Safety First - Environmental Friendly

N/A
  • CFC free R134a refrigerant.
  • CSA approved.

Time Proven Design

Time Proven Design

N/A
  • 316 stainless steel, brazed plate heat exchangers efficiently dry the air to the specified pressure dew point.
  • Hot gas by-pass valve maintains constant evaporator temperature.
  • Replaceable ambient air filter protects the condenser from airborne contaminants
    • Maintenance kits include ambient air filter.

Condensate Management

Condensate Management

N/A
  • Integral stainless demister/separator captures liquid condensate and solid particles.
  • Electronic drain valve automatically discharges condensate from the dryer.

International Air Quality Class Standards

ISO 8573-1 Air Quality Standard

N/A ISO 8573-1, the international standard for compressed air quality, defines the amount of contamination permissible in compressed air.
The ISO standard identifies three primary forms of contamination in compressed air systems - solid particles, water and oil Contaminants are classified and assigned a quality class, ranging from Class 0, the highest purity level, to Class 6, the most relaxed.

HPR and HPRN series refrigerated air dryers offer the perfect balance between technology and simplicity to dry compressed air systems to ISO 8573-1 Air Quality Class 4 to 5 - pressure dew points.

Option Pre-Filtration

N/A NGF series - PF grade filtration - removes solid and oil contaminants from the air stream before entering the dryer.

ISO Air Quality Class:
  • Solids - Class 2
  • Remaining Oil - Class 4
  • Removes solids 1.0 micron and larger
  • Remaining oil content 2.0. mg/m³

Option After-Filtration

N/A NGF series - HF grade filtration - provides high efficiency oil removal protecting downstream equipment .

ISO Air Quality Class:
  • Solids - Class 1
  • Remaining Oil - Class1
  • Removes 99.999+ % of solids ≥ 0.01 micron
  • Remaining oil content < 0.01 mg/m3
  • 1 Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 bar) and 100 ºF (38 ºC); ambient air temperature: 100 ºF (38 ºC); operating on 60 Hz power supply.