Energy Savings Control at Load 95% |
N/A 1694 USD |
Energy Savings Control at Load 90% |
N/A 3389 USD |
Energy Savings Control at Load 85% |
N/A 5083 USD |
Energy Savings Control at Load 80% |
N/A 6778 USD |
Energy Savings Control at Load 75% |
N/A 8472 USD |
Energy Savings Control at Load 70% |
N/A 10166 USD |
Energy Savings Control at Load 55% |
N/A 15250 USD |
Energy Savings Control at Load 40% |
N/A 20333 USD |
Energy Savings Control at Load 25% |
N/A 25416 USD |
Series |
N/A HHS |
Brands |
N/A SPX® |
Inlet Flow Capacity at 100 psig (6.7 bar) Pressure |
N/A 1350 scfm2294 nm³/h |
Height |
N/A 118 in |
Width |
N/A 60 in |
Depth |
N/A 56 in |
Inlet Connection Size |
N/A 3 in |
Inlet Connection Type |
N/A ANSI Flange |
Outlet Connection Size |
N/A 3 in |
Outlet Connection Type |
N/A ANSI Flange |
Weight |
N/A 3722 lb |
Note for Connections |
N/A BSP and DIN flanges available. |
Maximum Standard Working Pressure1 | N/A 150 psig10.5 bar |
Maximum Optional Working Pressure |
N/A 250 psig17.6 bar |
Minimum Operating Pressure |
N/A 60 psig120 psig150 psig250 psig4.2 bar8.4 bar10.5 bar17.6 bar |
Maximum Inlet Air or Ambient Air Temperature |
N/A 120 ºF49 ºC |
Pressure Drop at Rated Flow |
N/A ≤ 5 psi≤ 0.35 bar |
Available Voltage |
N/A 100 to 240 V |
Phase |
N/A 1 |
Frequency |
N/A 50 to 60 Hz |
Direct Current (DC) Voltage |
N/A 12 to 24 V |
Industry Standards/Certifications |
N/A ANSI ASME Approved CRN NEMA 4 |
Industry |
N/A Industries such as pharmaceutical manufacturing, laboratories, hospitals, microelectronics, food packaging, paper, glass and powder painting with low dew point requirements, utilize heatless desiccant air dryers. |
Dew Point |
N/A -100 ºF38 ºF-4 ºF-40 ºF-20 ºC3 ºC-40 ºC-73 ºC |
Remaining Moisture at Dew Point -100 ºF (-73 ºC) |
N/A 0.12 ppmw0.15 mg/m³ |
Remaining Moisture at Dew Point -40 ºF (-40 ºC) |
N/A 10 ppmw12 mg/m³ |
Remaining Moisture at Dew Point -4 ºF (-20 ºC) |
N/A 81 ppmw97 mg/m³ |
Remaining Moisture at Dew Point 38 ºF (3 ºC) |
N/A 610 ppmw730 mg/m³ |
Cycle Time for ISO Quality Class 1 |
N/A 4 min. Fixed |
Cycle Time for ISO Quality Class 2 |
N/A 10 min. Fixed Demand |
Cycle Time for ISO Quality Class 3 |
N/A 16 min. Fixed Demand |
Cycle Time for ISO Quality Class 4 |
N/A 24 min. Fixed Demand |
Industry-Leading Design |
N/A
|
Integrated Filtration |
N/A
|
Precision AccuShift™ Switching Valves |
N/A
|
Engineered-to-Order Options |
N/A
|
Safety Built to Code |
N/A
|
How it Works |
N/A
|
Match Performance by Demand |
N/A
Three user selectable designs engineered to balance economy and performance. Ideal for applications that operate with a large swing in air demands due to variations in production scheduling or shifts of operation. Some applications operate at a fraction of the flow of the compressor due to air system efficiency improvements. Some applications operate continuously at-or-near full capacity. |
Automatic SensaTherm® Energy Savings |
N/A
Hankison®'s HHS Series with patented SensaTherm® automatically matches purge air to plant air demand. This ensures maximum performance as the saved energy goes right to your bottom line. When operating at reduced capacity, the on-line drying tower remains active longer, until its full drying capacity is utilized. Desiccant bed temperature changes are constantly monitored within each tower to precisely manage drying times and reduce purge air consumption. SensaTherm® also measures the increase in desiccant bed temperature (heat of adsorption) during the drying stage and the decrease in desiccant bed temperature (heat of desorption) during the regeneration stage. These temperature changes are accurate indicators of the moisture load on the dryer. This data is interpreted by microprocessor based controls to determine how long a tower stays on-line during the drying stage. |
Advantages |
N/A
|
Controller Features |
N/A
|
Inlet Flow |
N/A Inlet flow capacities are established in accordance with CAGI (Compressed Air and Gas Institute) standard ADF-200: Inlet air pressure 100 psig (6.7 barg), inlet temperature saturated at 100 ºF (38 ºC). To determine inlet flow at pressures other than 100 psig (6.7 barg), multiply inlet flow at 100 psig (6.7 barg) from Product Specifications by the corresponding multiplier. |
Four Dew Point Options per ISO 8573-1 Air Quality Standards |
N/A Specifying a pressure dew point is not simple work for an engineer. Hankison® Heatless dryer designs allow you to optimize performance and dew points in the field to adapt to your environment and meet the following ISO 8573-1 Classes of air quality. |
Dedicated to Excellence |
N/A
Since 1948, compressed air users around the world have relied on Hankison® to provide innovative compressed air treatment solutions for critical applications. Hankison® maintains a long standing reputation for manufacturing products that deliver superior performance, time proven reliability and optimal energy savings. Hankison® today is the preferred choice for providing clean, dry compressed air for the most challenging industries. |