|
|
|
|
|
7003107 - Distributor - Condensate Management System 7024380 - CTS30/60 Level Minder Oil Container Alarm System 7024382 - 1 Kilowatts (kW) Heater for CTS30/60
|
|
|
|
Compressed air is compressed and discharged at elevated temperatures in a saturated state. As the air cools through aftercoolers, dryers, or pipelines, the water vapor condenses into a liquid form which then mixes with the normal oil carryover from the compressor. The condensate becomes contaminated by the oil and must be treated before expelling it into a sewer system or onto the ground. The oil must be separated from the condensate and only the condensate can be expelled. The oil must be reclaimed and disposed of in an environmentally safe manner.
Untreated condensate can have detrimental effects on the environment and is illegal to dump into sewer systems or onto the ground.
|
|
|
|
Even lubricants of the same base stock perform differently, depending upon the additives used. This becomes especially important when trying to separate lubricant from condensed water in a compressed air system.
That is why Gardner Denver™ has custom engineered our lubricants to give you maximum performance. AEON® lubricants provide extra value in dollars you can see.
Our AEON® lubricants have superior demulsibility which enhances the overall system performance from the compressor's operation to the condensate disposal. Many competitive lubricants take longer to separate, thus requiring larger oil/water separators at higher costs. Using the Eliminator II™ with AEON® lubricants saves you big money up front and over the life of the system.
|
|
|
|
Untreated condensate can have detrimental effects on the environment and is illegal to dump into sewer systems or onto the ground.
Inlet Diffuser rotates at 90º intervals & has 3 condensate inlets for maximum installation flexibility.
Separation Filter coalesces small oil droplets into larger ones allowing them to float freely on the surface.
Sediment Chamber collects rust & scale, avoiding carbon fouling; removable chamber for easy cleaning.
Water Outlet Port located in back of unit to easily pipe into drain.
Large Vessel for maximum residence time.
Wider Carbon Bed with up to 40% more carbon provides extended service intervals and improved performance in hot, humid summertime conditions.
Translucent Oil Container comes standard and allows for easy oil disposal.
Sample Valve is conveniently located and samples condensate from 2/3 into the carbon depth - allows time to re-order carbon replacement, while remaining within the legal limit.
Oil Outlet Tube is fully adjustable to precisely set the depth of the lubricant level for optimum performance.
Pre-Absorption Chamber unique material breaks contaminate formed emulsions, allowing for more efficient separation.
Suspended Carbon Bed handles (CTS30 and larger) assist in carbon replacement.
Pop-Up Flow Indicator identifies restricted flow condition; stays up until manually reset.
Sample Test Jars (2) for a quick visual check of water-out vs. standard tap water; if the water out is cloudy, carbon needs replacement.
|
|
|
|
- Designed & Rated for Real Life Summertime Conditions: 90 ºF and 90 % RH.
- Reduced Maintenance: 40% longer service life than most competitive units.
- Carbon bed handles for easy carbon change out.
- Pop Up Indicator: Stores evidence of restricted flow conditions until manually reset.
- Unique Pre-Absorption Filter: Breaks contaminate formed emulsions.
|
|
|
|
- Distributor: Used to collect and evenly distribute flow into multiple units; also recommended for use with high capacity demand drains to protect Eliminator II™ from large condensate surges.
- Remote Flow Indicator: For remote alarming of a reduced flow condition.
- Level Minder: Remote indication of when oil container needs replacement.
- Heater: For use when ambient temperatures are subject to freezing.
|
|
|
|
Let us show you how we can provide more value for less!
Ratings based on rotary screw air compressor operating on AEON® 9000SP. Ratings may be increased by 25% if a refrigerated air dryer is not used. Please consult your Gardner Denver™ distributor for proper sizing when using other types of lubricants or compressors. Eliminator II™ is not recommended for use with emulsifying lubricant such as Polyglycol, ATF, or Motor Oil lubricants with heavy additive packages.
|
|
|