Print Back
The CTS Eliminator II™

Designed as an effective and reliable means of treating lubricant-contaminated compressor condensate, the CTS Eliminator II™ separates oil for easy disposal.
Unit of Measure

Specifications

Maximum Capacity at 90 ºF Temperature and 90% Relative Humidity

N/A 150 ft³/min

Maximum Capacity at 70 ºF Temperature and 70% Relative Humidity

N/A 357 ft³/min

Weight

N/A 53 lb

Ambient Temperature

N/A +32 to -120 ºF

Inlet Temperature

N/A 120 ºF

Number of Condensate Inlets

N/A 3

Condensate Inlets Size

N/A 1/2

Condensate Inlet Connection Type

N/A NPT

Oil Container Volume

N/A 2 1/2 gal

Water Outlet Port

N/A "G" NPT

Number of Sample Jars

N/A 2

Maintenance Kits

N/A Convenient Pre-Packaged Filter Kits include Expansion Chamber Elements, Separation Filters, Pre-Absorption Filters, and Carbon Beds

Maintenance Kit Part Number

N/A 7024364

Industry Standards/Certifications

N/A Compressed Air and Gas Institute (CAGI) Energy Star Partner ISO 9001:2008

Dimensions

A

N/A 29.75 in

B

N/A 27.00 in

C

N/A 20.75 in

D

N/A 11.25 in

E

N/A 5.25 in

F

N/A 16.00 in

G

N/A .75 in

H

N/A 26.50 in

J

N/A 26.00 in

K

N/A 9.00 in

L

N/A 14.00 in

M

N/A 19.50 in

N

N/A 4.50 in

P

N/A 2.75 in

Q

N/A 4.50 in

R

N/A 4.00 in

Note for Dimensional Data

N/A Tolerances - all dimensions are ±0.50 unless otherwise shown.
Diffuser is rotatable in 90 degree increments.
When properly maintained, the Eliminator II™ will have discharge water containing less than 15 ppm of oil remaining.

Recommended Accessories

Recommended Accessories

N/A 7003107 - Distributor - Condensate Management System
7024379 - CTS15 Level Minder Oil Container Alarm System
7024381 - 0.5 Kilowatts (kW) Heater for CTS15

A Cleaner Environment and Reduced Disposal Costs

A Cleaner Environment and Reduced Disposal Costs

N/A Compressed air is compressed and discharged at elevated temperatures in a saturated state. As the air cools through aftercoolers, dryers, or pipelines, the water vapor condenses into a liquid form which then mixes with the normal oil carryover from the compressor. The condensate becomes contaminated by the oil and must be treated before expelling it into a sewer system or onto the ground. The oil must be separated from the condensate and only the condensate can be expelled. The oil must be reclaimed and disposed of in an environmentally safe manner.

Did you Know Not All Lubricants are Created Equal?

Did you Know Not All Lubricants are Created Equal?

N/A Even lubricants of the same base stock perform differently, depending upon the additives used. This becomes especially important when trying to separate lubricant from condensed water in a compressed air system.

That is why Gardner Denver™ has custom engineered our lubricants to give you maximum performance. AEON® lubricants provide extra value in dollars you can see.

Our AEON® lubricants have superior demulsibility which enhances the overall system performance from the compressor's operation to the condensate disposal. Many competitive lubricants take longer to separate, thus requiring larger oil/water separators at higher costs. Using the Eliminator II™ with AEON® lubricants saves you big money up front and over the life of the system.

Additional Information

Additional Information

N/A Untreated condensate can have detrimental effects on the environment and is illegal to dump into sewer systems or onto the ground.

Inlet Diffuser rotates at 90º intervals & has 3 condensate inlets for maximum installation flexibility.

Separation Filter coalesces small oil droplets into larger ones allowing them to float freely on the surface.

Sediment Chamber collects rust & scale, avoiding carbon fouling; removable chamber for easy cleaning.

Water Outlet Port located in back of unit to easily pipe into drain.

Large Vessel for maximum residence time.

Wider Carbon Bed with up to 40% more carbon provides extended service intervals and improved performance in hot, humid summertime conditions.

Translucent Oil Container comes standard and allows for easy oil disposal

Sample Valve is conveniently located and samples condensate from 2/3 into the carbon depth - allows time to re-order carbon replacement, while remaining within the legal limit.

Oil Outlet Tube is fully adjustable to precisely set the depth of the lubricant level for optimum performance.

Pre-Absorption Chamber unique material breaks contaminate formed emulsions, allowing for more efficient separation.

Pop-Up Flow Indicator identifies restricted flow condition; stays up until manually reset.

Sample Test Jars (2) for a quick visual check of water-out vs. standard tap water; if the water out is cloudy, carbon needs replacement.

Features/Benefits

Features/Benefits

N/A
  • Designed & Rated for Real Life Summertime Conditions: 90 ºF and 90 % RH.
  • Reduced Maintenance: 40% longer service life than most competitive units.
  • Pop Up Indicator: Stores evidence of restricted flow conditions until manually reset.
  • Unique Pre-Absorption Filter: Breaks contaminate formed emulsions.

Accessories

Accessories

N/A
  • Distributor: Used to collect and evenly distribute flow into multiple units; also recommended for use with high capacity demand drains to protect Eliminator II™ from large condensate surges.
  • Remote Flow Indicator: For remote alarming of a reduced flow condition.
  • Level Minder: Remote indication of when oil container needs replacement.
  • Heater: For use when ambient temperatures are subject to freezing.

Note

Note

N/A Let us show you how we can provide more value for less!

Ratings based on rotary screw air compressor operating on AEON® 9000SP. Ratings may be increased by 25% if a refrigerated air dryer is not used. Please consult your Gardner Denver™ distributor for proper sizing when using other types of lubricants or compressors. Eliminator II™ is not recommended for use with emulsifying lubricant such as Polyglycol, ATF, or Motor Oil lubricants with heavy additive packages.