Items |
XMX100 XMX Series - Demand Expander Control System |
XMX1.500 XMX Series - Demand Expander Control System |
XMX1200 XMX Series - Demand Expander Control System |
XMX1300 XMX Series - Demand Expander Control System |
XMX1400 XMX Series - Demand Expander Control System |
|||||
Capacity | N/A 500 scfm | N/A 750 scfm | N/A 1000 scfm | N/A 2000 scfm | N/A 3200 scfm | |||||
Inlet Connection | N/A 1" NPT | N/A 1.5" NPT | N/A 2" FLG. | N/A 3" FLG. | N/A 4" FLG. | |||||
Outlet Connection | N/A 1.5" NPT | N/A 2" NPT | N/A 3" FLG. | N/A 4" FLG. | N/A 6" FLG. | |||||
Length | N/A 32 in | N/A 34 in | N/A 44 in | N/A 51 in | N/A 57 in | |||||
Width | N/A 12 in | N/A 14 in | N/A 18 in | N/A 20 in | N/A 22 in | |||||
Height | N/A 12 in | N/A 15 in | N/A 20 in | N/A 24 in | N/A 31 in | |||||
Weight | N/A 250 lb | N/A 275 lb | N/A 295 lb | N/A 375 lb | N/A 625 lb | |||||
Technical Information |
N/A
Storage Management
In conventional system designs, the storage (if it exists at all) is merely an extension of the piping and distribution system. When the Supply and the Demand are separated, storage can be reserved to handle instantaneous system events or compressor failures. The compressor automation system control is enhanced with the advantage of real storage when a Demand Expander is added to the system. Artificial Demand is reduced because lower system pressures equate to lower system flows. Leaks will waste less air volume when pressure is reduced. Leaks will also be slower to expand under lower controlled pressure. Unregulated flows will also consume less air as a result of the Demand Expander. System Security The plant can now operate at pressure never before believed achievable due to the security provided by stored upstream volume in the air receivers. System events are not seen by the process. System Stability Most compressed air systems experience pressure fluctuations of 10% to 20%. As compressed air is an ingredient in the plant process, this inconsistency will have a negative impact on production. With Demand Expansion, the process sees only a constant pressure regardless of demand or coincidental system events. Maximizes Compressor Efficiency The use of storage provides the compressor control the ability to make a measured response to a fall or rise in the storage receivers. With an ESP 20/20 compressor controller, the Rate of Pressure Change in the storage receivers is calculated by the unique Bullseye algorithm and intelligent, energy efficient loading and operational decisions will be made. Fail-Safe Operation The XMX Series Demand Expander is provided with a fail open valve both electronically and pneumatically. Should the air signal or the control signal fail, the valve will open 100%. A manual three valve by-pass is included on the assembly to provide for continued air flow during valve maintenance periods. Demand Expander Control The Demand Expander can receiver its control from the Gardner Denver ESP 20/20 Compressed Air Management System or from a stand-alone electronic controller. Both methods provide equal control accuracy. Combining both compressor and Demand Expander control through the ESP 20/20 provides for the coordination of all setpoints to assure maximum system efficiency. Optional Features |
|||||||||
|