Optimal System Protection
Hankison’s DHW Series Wall Mount Desiccant Air Dryers protect moisture sensitive applications requiring low pressure dew points. Delivers dew points of ISO 8573-1: 2010 Class 1 (-100 ºF, -73 ºC) and Class 2 (-40 ºF, -40 ºC) with flow rates of 7 to 50 scfm (12 to 85 nm³/h).
Hankison’s DHW Series Wall Mount Desiccant Air Dryers protect moisture sensitive applications requiring low pressure dew points. Delivers dew points of ISO 8573-1: 2010 Class 1 (-100 ºF, -73 ºC) and Class 2 (-40 ºF, -40 ºC) with flow rates of 7 to 50 scfm (12 to 85 nm³/h).
                    Unit of Measure
                    
               
        
            Specifications
| Inlet Flow Capacity at -40 ºF (-40 ºC) | N/A 7 scfm12 nm³/h | 
| Inlet Flow Capacity at -100 ºF (-70 ºC) | N/A 5 scfm9 nm³/h | 
| Inlet Connection Size | N/A 0.5 in | 
| Outlet Connection Size | N/A 0.5 in | 
| Inlet Connection Type | N/A NPT | 
| Outlet Connection Type | N/A NPT | 
| Height | N/A 30.5 in | 
| Width | N/A 17.52 in | 
| Depth | N/A 6.69 in | 
| Weight | N/A 55 lb | 
| Industry Standards/Certifications | N/A Compressed Air and Gas Institute (CAGI) ISO 8573-1:2010 | 
| Series | N/A DHW | 
| Brands | N/A Hankison® | 
| Dew Points of ISO 8573-1: 2010 Class 1 | N/A -100 ºF-73 ºC | 
| Dew Points of ISO 8573-1: 2010 Class 2 | N/A -40 ºF-40 ºC | 
Supreme Craftsmanship
| Standard Cord Set Size | N/A 6 ft1.8 m | 
| Furnished in Cabinet for Easy Wall Mounting | N/A 
 | 
| Front Mounted Control Panel | N/A 
 | 
| Highly Accurate Solid State Timer | N/A 
 | 
| Optional NGF Series Filter Packages | N/A 
 | 
Technology at a Glance
| Technology at a Glance | N/A 
 | 
How it Works
| How it Works | N/A
                                                                                          Compressed air enters the dryer and is directed to Tower 1 by valve (A), and then to the dryer outlet through shuttle valve (B). A portion of the dried air is throttled to near atmospheric pressure by means of orifice (C). This extremely dry, low pressure air flows through and regenerates the desiccant in Tower 2 and is exhausted through purge/repressurization valve (D) and exhaust muffler (E) to atmosphere. After a set time, the automatic solid state timer closes purge/ repressurization valve (D) allowing Tower 2 to repressurize slowly. At the end of 2 minutes, valve (A) shifts and purge/repressurization valve (D) reopens. The main air flow is now dried by Tower 2 while Tower 1 is being regenerated. | 
 
  
                             
  
  
  
  
  
 