The new CTS Eliminator II has been designed as an effective and reliable means of treating lubricant contaminated compressor condensate.

Compressed air is discharged at elevated temperatures in a saturated condition. Any cooling which takes place through aftercoolers, dryers, or pipelines cause the water vapor to condense into a liquid form, which then mixes with any oil carryover of a machine. This contaminated condensate cannot be disposed of into sewer systems, or onto the ground, without being properly treated.

Tolerances - all dimensions are +/- .50 unless otherwise shown
Diffuser is rotatable in 90 degree increments
When properly maintained, the Eliminator II will have discharge water containing less than 15 ppm of oil remaining

Ratings based on rotary screw air compressor operating on AEON 9000 SP. Ratings may be increased by 25% if a refrigerated air dryer is not used. Please consult your Gardner Denver distributor for proper sizing when using other types of lubricants or compressors. Eliminator II is not recommended for use with emulsifying lubricant such as Polyglycol, ATF, or Motor Oil lubricants with heavy additive packages.
Unit of Measure

Specifications

Max CFM Capacity at 90 ºF/90%RH

N/A 300 cfm

Max CFM Capacity at 70 ºF/70%RH

N/A 714 cfm

Ambient Temperature

N/A +32-120 ºF

Inlet Temperature

N/A 120 ºF

Weight

N/A 77 lb

A

N/A 39.00 in

B

N/A 36.25 in

C

N/A 29.75 in

D

N/A 17.00 in

E

N/A 6.25 in

F

N/A 22.75 in

G

N/A .75 in

H

N/A 34.00 in

J

N/A 32.00 in

K

N/A 12.50 in

L

N/A 15.00 in

M

N/A 21.00 in

N

N/A 7.50 in

P

N/A 3.50 in

Q

N/A 6.50 in

R

N/A 5.25 in

Maintenance Kits

N/A 7024365

Technical Information

N/A Not all lubricants are created equal? Even lubricants of the same base stock perform differently, depending upon the additives used.
This becomes especially important when trying to separate lubricant from condensed water in a compressed air system.

That is why Gardner Denver has custom engineered our lubricants to give you maximum performance. AEON™ lubricants provide extra value in dollars you can see.

Our superior demulsibility enhances overall system performance from compressor operation to condensate disposal. Many competitive lubricants take longer to separate, thus requiring larger oil/water separators at higher costs. Using the Eliminator II with AEON lubricants saves you big money up front and over the life of the system.

Let us show you how we can provide more value for less!

Features/Benefits

  • Designed & Rated for Real Life Summertime Conditions – 90ºF 90% RH
  • Reduced Maintenance – 40% longer service life than most competitive units
  • Vaccu-Break Conduit – (CTS60 & Above) & carbon bed handles (CTS30 & above) for easy carbon changeout
  • Pop Up Indicator – Stores evidence of restricted flow conditions until manually reset
  • Unique Pre-Absorption Filter – Breaks contaminate formed emulsions

  • Accessories

    N/A DISTRIBUTOR– Used to collect and evenly distribute flow into multiple units; also recommended for use with high capacity demand drains to protect Eliminator II from large condensate surges

    Remote Flow Indicator –
    For remote alarming of a reduced flow condition

    Level Minder
    – Remote indication of when oil container needs replacement

    Heater
    – For use when ambient temperatures are subject to freezing

    Recommended Accessories
    7003107 - DISTRIBUTOR - Condensate Management System
    7024378 - Remote Flow Indicator
    7024379 - CTS15 Level Minder Oil Container Alarm System
    7024380 - CTS30/60 Level Minder Oil Container Alarm System
    7024381 - .5 KW Heater for CTS15
    7024382 - 1 KW Heater for CTS30/60 (2 each required for CTS60)